XC2EDGVH-5.08mm
During the use of terminal blocks, some common faults may occur, such as improper fixing. To prevent this, XC technicians suggest the following:
1. Interchangeability Check
The interchangeability check is a dynamic inspection process. It ensures that plugs and sockets of the same series can be connected to each other to detect any issues, such as dimensional inaccuracies in insulators or contacts, missing parts, or improper assembly. These issues can prevent proper mating, positioning, and locking, or even cause disintegration under rotational forces. Another benefit of the interchangeability check is that it can promptly detect any excess metal that could affect insulation performance through threaded or bayonet connections. Therefore, terminal blocks used in critical applications should undergo 100% inspection to avoid major and catastrophic failures.
2. Torque Test
The torque test is an effective method for assessing the structural reliability of terminal blocks. As specified in the US military standard MIL-L-39012, samples should be randomly selected from each batch for torque testing to quickly identify any potential problems.
3. Throughput Testing of Crimped Wires
During electrical assembly, it is often found that some crimped wires are not properly inserted or fail to lock after insertion, resulting in unreliable contact. Analysis indicates that burrs or dirt may be present on the threads of some mounting holes, causing jamming. This is particularly noticeable in the last few mounting holes of a connector that has already been assembled by the user. Upon discovering this defect, it is necessary to remove all crimped wires from the other holes and replace the connector. Additionally, improper matching of wire diameter and crimp hole diameter, or errors in the crimping process, can also lead to loose crimped connections.

| UL/CUL Techical Date | |||
| Use Grroup | B | C | D |
| Rated Voltage(V) | 300 | . | 300 |
| Rated Current(A) | 10 | . | 10 |
| Wire Range Solid/Stranded(AWG) |
. | ||
| Withstanding VOLTAGE | 1600V/Min | ||
| IEC Techical Date | |||
| Overvoltage Category | Ⅲ | Ⅲ | Ⅱ |
| Contamination Class | 3 | 2 | 2 |
| Rated Voltage(V) | . | 320 | 630 |
| Rated Current(A) | . | 15 | 15 |
| Impulse Withstand Voltagea(KV) | . | 4.0 | 4.0 |
| Conductor cross section Solid/Flexible(mm³) |
. | ||
| Material | |||
| Lnsulation Material | Termoplastic | ||
| Contactor Material | Copper alloy | ||
| Contactive Coating | Tin plated | ||
| Mechanical | |||
| Pitch (mm) | 5.08 | ||
| Poles (p) | 2*(2-24) | ||
| Stripping Length(mm) | . | ||
| Screw/Torque(Max)(N.M) | . | ||
| Operating temperatur(℃) | -40-+105 | ||
| Pin Dimensions | 4.0 | ||
| PCB Hole Diameter(mm) | 1.6 | ||
Hot Tags: 2edgvh-5.08 pluggable terminal block, China 2edgvh-5.08 pluggable terminal block manufacturers, factory, 2EDGV 5 0 Plug in Type Terminal Block, 2EDGRM 7 62 Plug in Type Terminal Block, 15EDGVM 3 5 Plug in Type Terminal Block, 2EDGKB 7 5 Plug in Type Terminal Block, 15EDGKA 3 5 Plug in Type Terminal Block, SV 3 5 Pluggable Terminal Block