XC2EDGKBM-5.08
Terminal blocks often experience faults during use, such as poor contact. To prevent this, XC technicians recommend the following:
1.Continuity Testing: This is generally not included in the acceptance testing of terminal block manufacturers, but users often request continuity testing after installation. Therefore, it is recommended that manufacturers add 100% point-by-point continuity testing for certain key models.
2.Momentary Power Loss Testing: Some terminal blocks are used in dynamic vibration environments. Experiments have shown that checking only the static contact resistance is not enough to guarantee reliable contact under dynamic conditions. Connectors with acceptable contact resistance may still experience momentary power loss during vibration and impact simulation tests. Therefore, for terminal blocks with high reliability requirements, 100% dynamic vibration testing should be performed to assess contact reliability.
3.Single-Hole Separation Force Testing: Single-hole separation force refers to the force required to move the contact parts from a stationary to a moving state while they are in contact. It is used to characterize the contact between the pin and the socket. Experiments show that insufficient single-hole separation force can cause momentary signal interruption under vibration and impact loads. Measuring single-hole separation force is more effective than measuring contact resistance when checking contact reliability. Even if the contact resistance meets the requirements, the single-hole separation force may still be out of tolerance. Therefore, in addition to developing a new generation of flexible, stable, and reliable contact components, manufacturers should avoid using automatic insertion and extraction force testing machines for multi-point simultaneous testing on key models. Instead, they should conduct 100% point-by-point single-hole separation force checks on finished products to prevent momentary signal interruptions caused by loosening of individual holes.

| UL/CUL Techical Date | |||
| Use Grroup | B | C | D |
| Rated Voltage(V) | 300 | . | 300 |
| Rated Current(A) | 10 | . | 10 |
| Wire Range Solid/Stranded(AWG) |
24-12 | ||
| Withstanding VOLTAGE | 1600V/Min | ||
| IEC Techical Date | |||
| Overvoltage Category | Ⅲ | Ⅲ | Ⅱ |
| Contamination Class | 3 | 2 | 2 |
| Rated Voltage(V) | . | 320 | 630 |
| Rated Current(A) | . | 15 | 15 |
| Impulse Withstand Voltagea(KV) | . | 4.0 | 4.0 |
| Conductor cross section Solid/Flexible(mm³) |
2.5 | ||
| Material | |||
| Lnsulation Material | Thermoplastic | ||
| Contactor Material | Copper alloy | ||
| Contactive Coating | Tin plated | ||
| Mechanical | |||
| Pitch (mm) | 5.08 | ||
| Poles (p) | 2-24 | ||
| Stripping Length(mm) | 7-8 | ||
| Screw/Torque(Max)(N.M) | M2.5/0.4 | ||
| Operating temperatur(℃) | -40-+105 | ||
| Pin Dimensions | . | ||
| PCB Hole Diameter(mm) | . | ||
Hot Tags: 2edgkbm-5.08 plug-in type terminal block, China 2edgkbm-5.08 plug-in type terminal block manufacturers, factory, 2EDGV 5 0 Plug in Type Terminal Block, 2EDGRM 7 62 Plug in Type Terminal Block, 15EDGVM 3 5 Plug in Type Terminal Block, 2EDGKB 7 5 Plug in Type Terminal Block, 15EDGKA 3 5 Plug in Type Terminal Block, SV 3 5 Pluggable Terminal Block