The XCDS-6 is a 6 mm² slide-type disconnect terminal block for electrical control panels, switchgear, and power distribution assemblies.
The terminal block uses an M4 bolt connection for ring cable lugs and incorporates a sliding disconnect mechanism for circuit isolation during testing, measurement, and maintenance.
Its compact 11 mm width is intended for DIN-rail-mounted terminal assemblies. The exact conductor range, electrical ratings, mounting compatibility, and applicable approvals should be confirmed against the current technical datasheet.
Key Features
M4 Bolt Connection
The XCDS-6 uses an M4 bolt connection for ring cable lugs. The required lug dimensions and conductor preparation should be selected according to the applicable terminal specification.
Sliding Disconnect Mechanism
The integrated sliding mechanism allows the circuit to be disconnected without removing the conductor from the terminal connection.
Insulated Housing
The terminal block incorporates an insulating housing around the conductive components. The exact protection characteristics should be confirmed according to the applicable product and test specifications.
Compact Terminal Profile
The terminal block has an 11 mm width and is designed for DIN-rail mounting. Compatible rail types should be confirmed from the manufacturer's dimensional drawing.
Product Range
XCDS-6
Standard disconnect terminal block configuration.
XCDS-6-PE
PE/grounding version. The electrical connection between the grounding terminal and DIN rail should be confirmed from the product construction and applicable test documentation.
Custom Configurations
Custom housing colors, marking, packaging, and other configurations may be available subject to production requirements and minimum order quantities.
Technical Specifications
|
Technical Parameter |
Specification |
|
Model |
XCDS-6 |
|
Rated Cross Section |
6 mm² |
|
Compatible Conductor Range |
To be confirmed |
|
Rated Voltage |
1000 V, subject to applicable test conditions |
|
Rated Current |
36 A, subject to applicable test conditions |
|
Connection Method |
M4 bolt connection |
|
Terminal Width |
11 mm |
|
Insulating Material |
PA66 |
|
Flammability Rating |
UL 94 V-0, subject to material certification |
|
Impulse Withstand Voltage |
8 kV, subject to applicable test conditions |
|
Operating Temperature |
-60°C to +110°C, subject to product specification |
|
Applicable Standard |
IEC 60947-7-1, subject to product test documentation |
|
UL Status |
To be confirmed |
|
CE Compliance Documentation |
To be confirmed |
|
RoHS Compliance |
To be confirmed |
|
Compatible DIN Rail |
To be confirmed |
Technical Documents
2D/3D CAD files, dimensional drawings, product datasheets, test reports, and conformity documentation should be provided according to the actual product configuration.
Applications
The XCDS-6 can be considered for terminal connection and circuit isolation requirements in electrical assemblies such as:
Industrial Control Panels
Terminal assemblies used for machine control and electrical distribution.
Switchgear and Electrical Cabinets
Applications requiring organized conductor termination and circuit isolation within control or distribution enclosures.
Instrumentation and Measurement Panels
Applications where circuits may need to be isolated during electrical testing or maintenance.
Power Distribution Assemblies
Applications requiring a bolt-connected terminal configuration for specified conductors.
Application suitability should be evaluated according to voltage, current, conductor type, installation environment, applicable standards, and required accessories.
Customization and OEM/ODM
Customization options can be evaluated according to project requirements.
Potential customization areas include:
Housing Color
Custom colors for circuit identification, subject to available materials and production requirements.
Product Marking
Customized terminal identification or marking according to approved drawings and production specifications.
Packaging
Customized labeling and packaging formats for distribution or OEM programs.
Assembly
Pre-assembled terminal configurations may be evaluated according to customer drawings and required components.
For OEM/ODM projects, customers should provide the required dimensions, electrical ratings, marking requirements, packaging specifications, annual demand, and applicable standards.
Manufacturing and Quality Control
Product manufacturing and quality-control information should be presented according to documented production and inspection capabilities.
Material Control
PA66 insulating material should be controlled according to the specified material grade and applicable flammability requirements. Material documentation should be available where required.
Molding and Tooling
Injection molding and tooling processes are used to produce the insulating housing. Actual dimensional tolerances should be specified according to the controlled product drawings.
Electrical Testing
Electrical tests should be conducted according to the applicable product specification and relevant standards. The exact test voltage, duration, acceptance criteria, and test method should be confirmed from the manufacturer's test documentation.
Mechanical Testing
Mechanical tests such as conductor retention or terminal strength should be specified only when corresponding test procedures and results are available.
Traceability
Batch, material, production, and inspection traceability should be described according to the manufacturer's actual quality-control system.
Frequently Asked Questions
Request a Quote
For an engineering review and quotation, please provide:
Required Model: XCDS-6 or specified alternative
Required Quantity: Annual and order quantity
Conductor Specification: Cross section and conductor type
Electrical Requirements: Voltage and current
DIN Rail Specification: Rail type and mounting requirements
Required Approvals: UL, CE, RoHS, IEC, or other applicable requirements
Customization: Color, marking, packaging, or assembly requirements
Existing Part Number: If the XCDS-6 is being evaluated as a replacement or alternative
Technical drawings, CAD files, test documentation, and quotation details can be provided according to the confirmed product configuration.
Hot Tags: xcds-6 disconnect terminal block, China xcds-6 disconnect terminal block manufacturers, factory